Autoclaves

Laboratory autoclaves AXIOM V-series are characterized by their modern design, user-friendly functions and state-of-the-art technology.
AXIOM V-series autoclaves are fitted ex-factory with a temperature-controlled door lock according to Pressure Vessel Regulations for the sterilization of liquids and according to ISO/DIN regulations.
In addition, the doors remains locked as long as there is excess pressure in the chamber.
Control mechanisms:
A specially developed microprocessor regulates all the functions of the autoclave. These include steam pressure, temperature, sterilization time as well as the optional functions of rapid cooling, pre- and post-vacuum and drying. In cases of deviation from the set values, a corresponding alarm is displayed.
Control is by menu and easy to operate. All sterilization parameters can be altered by using special numerical codes. The control panel is ergonomically integrated into the plastic lid cover of the autoclave.
FEATURES:
- Fully automatic, microprocessor control including 12 programs for the sterilisation of:
- Solids Waste
- destruction bags
- Liquid waste
- Liquid Media
- and for Cleaning
- Integrated separate steam generator (no heating elements in sterilization chamber)
- Novel safety ring-lock closure system with lip seal
- Temperature and steam pressure up to 140∞C / 4 bar, extendable to 150∞C / 5 bar
- Thermal lock: door lock controlled by pressure and medium temperature according to Pressure Vessel Regulations
- Flexible PT-100 temperature sensor for reference vessel
- Medium temperature-controlled sterilization time
- Electronic pressure transducer for pressure and temperature control
- "Autofill" - Automatic demineralized water feed for steam generation
- Special program for waste destruction with pulsating heat-up period for improved ventilation of waste bags
- Start by clock / timer for programmed start time
- Steam exhaust condensation, water cooled, thermostatic controlled
- Common collector connection for all outlets
- Emptying valve
- Base plate for vessels, baskets etc.
- Validation port
- RS 232 interface for external data transfer
- Prepared for subsequent printer installation
- Prepared for subsequent rapid cooling installation
- Prepared for subsequent installation of vacuum system
- Prepared for subsequent drying installation
- Safety cut of at low water level
- Safety cut of at excess temperature
| Type | Chamber dimensions | Chamber Volume |
|---|---|---|
| V-65 | 400 × 500 | 65 |
| V-75 | 400 × 600 | 75 |
| V-95 | 400 × 750 | 95 |
| V-100 | 500 × 500 | 100 |
| V-120 | 500 × 600 | 120 |
| V-150 | 500 × 750 | 150 |